G Delpon1, D Lazaro2, R de Crevoisier3
1Service de physique médicale, institut de cancérologie de l'Ouest, boulevard Jacques-Monod, 44805 Nantes Saint-Herblain, France.
Abstract:
Image-guided radiotherapy (IGRT) has become a standard irradiation technique to improve the clinical outcome of patients in terms of toxicity and local control due to better targeting of radiation during the irradiation fraction. Positioning imaging systems, whether embedded or not, such as kV for 2×2D acquisitions and especially kVCBCT for 3D acquisitions are however irradiating in a large volume including the target volume but also healthy tissue, with a theoretical risk of increased toxicity and second cancer. It therefore appears very important both to optimize the absorbed dose due to IGRT practice but also to report it, especially in case of kVCBCT. The AAPM report published in 2018 (« Image guidance doses delivered during radiotherapy: Quantification, management, and reduction ») proposes a management of image guidance doses delivered during radiotherapy. This report is the basis of this focus article that aims at giving orders of magnitude and proposing a management of image guidance doses delivered during radiotherapy in clinical practice. The dose delivered per kVCBCT is about 0.5 to 2 cGy at isocenter according to treatment site. As long as the calculation algorithms are not available in the treatment planning systems, it seems appropriate to use at least the published dose orders of magnitude. This estimate should ultimately allow the clinician to decide on the therapeutic strategy in the event of accumulation of positioning imaging sessions.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...