In vivo quantification of bone mineral density of lumbar vertebrae using fast kVp switching dual-energy CT:
Shuwei Zhou1,2, Lu Zhu3, Tian You1
1Department of Radiology, First Affiliated Hospital of Hunan University of Chinese Medicine, Changsha, China.
Background:
Osteoporosis is a common, progressive disease related to low bone mineral density (BMD). If it can be diagnosed at an early stage, osteoporosis is treatable. Quantitative computed tomography (QCT) is one of the current reference standards of BMD measurement, but dual-energy computed tomography (DECT) is considered to be a potential alternative. This study aimed to evaluate the feasibility and accuracy of phantomless in vivo DECT-based BMD quantification in comparison with QCT.
Methods:
A total of 128 consecutive participants who underwent DECT lumbar examinations between July 2018 and February 2019 were retrospectively analyzed. The density of calcium (water), hydroxyapatite (water), calcium (fat), and hydroxyapatite (fat) [DCa(Wa), DHAP(Wa), DCa(Fat) and DHAP(Fat), respectively] were measured along with BMD in the trabecular bone of lumbar level 1-2 by DECT and QCT. Linear regression analysis was performed to assess the relationship between DECT- and QCT-derived BMD at both the participant level and the vertebral level. Linear regression models were quantitatively evaluated with adjusted R-square, normalized mean squared error (NMSE) and relative error (RE). Bland-Altman analysis was conducted to assess agreement between measurements. P<0.05 was considered statistically significant.
Results:
Strong correlations were observed between DECT- and QCT-derived BMD at both the participant level and the vertebral level (adjusted R2 =0.983-0.987; NMSE = 1.6-2.1%; RElinear =0.6-0.9%). Bland-Altman plots indicated high agreement between both measurements. DCa(Fat) and DHAP(Fat) showed relatively similar and optimal predictive capability for QCT-derived BMD (both: adjusted R2 =0.987, NMSE =1.6%, RElinear =0.6%).
Conclusions:
Fast kVp switching DECT enabled accurate phantomless in vivo BMD quantification of the lumbar spine. DCa(Fat) and DHAP(Fat) had relatively similar and optimal predictive capability.
More Related Videos
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography