Related Experiment Video
Updated: Nov 23, 2025

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Human factors and usability of an incentive spirometer patient reminder (SpiroTimer™)
Joshua Pangborn1, Layla Kazemi1, Adam E M Eltorai2
1Brown University, Alpert Medical School, Providence, Rhode Island, United States.
Introduction:
To address the problem of incentive spirometry (IS) noncompliance, a use-tracking IS reminder device (SpiroTimer™) was developed. In a recent randomized clinical trial, the SpiroTimer™ improved IS use compliance, length of stay, and mortality. For successful, safe, and effective implementation of a new medical device, human factors and usability must be evaluated. This study aims to evaluate the SpiroTimer™'s human factors as they pertain to intended users, use environments, and uses.
Material And Methods:
Immediately following the completion of the randomized clinical trial of the SpiroTimer™, before the providers were informed of the results of the study, a human factors and usability survey was distributed in-person to all nurses involved in the trial. Variations in nurse user perspectives were evaluated.
Results:
A total of 52 nurses (100% response rate) completed the survey. In general, most nurses felt IS use compliance is poor (65%; 34/52, p = 0.0265) and should be improved (94%; 49/52, p < 0.001). Nurses agreed the SpiroTimer™ ameliorated patient IS use compliance (82%; 41/50, p < 0.001), IS effectiveness (74 %; 37/50, p < 0.001), and patient engagement in their own care (88%; 44/ 50, p < 0.001). Nurses reported the SpiroTimer™ helped remind them to work with their patients on IS (70%; 35/50, p = 0.0047) while reducing the number of times they had to remind their patients to use their IS (70%; 35/50, p = 0.0047). They felt that they would use the SpiroTimer™ with all their patients (82%; 41/50, p < 0.001) and that they would recommend the SpiroTimer™ to a colleague (74%; 37/50, p < 0.001). Ultimately, most nurses believed the SpiroTimer™ should become part of routine patient care (78%; 39/50, p < 0.001).
Discussion:
For a new medical technology to a medical device to be effectively implemented, human factors and usability must be demonstrated. Nurses believe the clinically effective SpiroTimer™ helps both patients and nurses and should become part of routine care.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Inhaled Medications
Mechanical Ventilation I: Indication and Settings
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...