Related Experiment Video
Updated: Nov 23, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Compressed sensing and parallel imaging accelerated T2 FSE sequence for head and neck MR imaging: Comparison of its
Hirotaka Ikeda1, Yoshiharu Ohno2, Kazuhiro Murayama3
1Department of Radiology, Fujita Health University School of Medicine, 1-98, Dengakugakubo, Kutsukake-cho, Toyoake, 470-1192, Aichi, Japan.
Purpose:
To directly compare the capability of compressed sensing (CS) and parallel imaging (PI) accelerated T2 FSE (Fast Spin Echo) sequence with PI for head and neck MR imaging.
Methods:
Thirty consecutive patients with various head and neck diseases (15 men and 15 women, mean age 53 ± 22 years) underwent MR imaging by PI with CS and by PI. Reduction factors were as follows: PI with CS, 3 and PI, 1.5. Examination times for PI with CS and PI were all recorded. For quantitative image quality assessment, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. For qualitative assessment, two investigators assessed overall image quality, artifacts and diagnostic confidence level using a 5-point scoring system, and final scores were determined by consensus of two readers. Mean examination time and all indexes were compared by means of paired t-test and Wilcoxon signed-rank test. Inter-observer agreement for each qualitative index was assessed in terms of kappa statistics.
Results:
Mean examination time for PI with CS (83.5 ± 11.0 s) was significantly shorter than that for PI (173.0 ± 54.4 s, p < 0.0001). SNR and CNR of PI with CS were significantly better than those with PI (mean SNR; 11.2 ± 3.6 vs 8.9 ± 2.6, median of CNR; 7.4 vs. 6.1, p < 0.0001). All inter-observer agreements were assessed as significant and substantial (0.62 < κ < 0.81).
Conclusion:
PI with CS accelerated T2 weighted sequence performs equally well or even slightly better than its PI accelerated, conventional counterpart at reduced scan times in the context of head and neck MR imaging.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...