Exhaled Breath and Oxygenator Sweep Gas Propionaldehyde in Acute Respiratory Distress Syndrome
Related Experiment Video
Updated: Nov 23, 2025

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Agnes S Meidert1, Alexander Choukèr1, Siegfried Praun2
1Department of Anesthesiology, University Hospital of Munich-Campus Großhadern, Ludwig-Maximilians-University of Munich, 81366 Munich, Germany.
Background:
Oxidative stress-induced lipid peroxidation (LPO) due to neutrophil-derived reactive oxygen species plays a key role in the early stage of the acute respiratory distress syndrome (ARDS). Monitoring of oxidative stress in this patient population is of great interest, and, ideally, this can be done noninvasively. Recently, propionaldehyde, a volatile chemical compound (VOC) released during LPO, was identified in the breath of lung transplant recipients as a marker of oxidative stress. The aim of the present study was to identify if markers of oxidative stress appear in the oxygenator outflow gas of patients with severe ARDS treated with veno-venous extracorporeal membrane oxygenation (ECMO).
Methods:
The present study included patients with severe ARDS treated with veno-venous ECMO. Concentrations of acetone, isoprene, and propionaldehyde were measured in inspiratory air, exhaled breath, and oxygenator inflow and outflow gas at corresponding time points. Ion-molecule reaction mass spectrometry was used to measure VOCs in a sequential order within the first 24 h and on day three after ECMO initiation.
Results:
Nine patients (5 female, 4 male; age = 42.1 ± 12.2 year) with ARDS and already established ECMO therapy (pre-ECMO PaO2/FiO2 = 44.0 ± 11.5 mmHg) were included into analysis. VOCs appeared in comparable amounts in breath and oxygenator outflow gas (acetone: 838 (422-7632) vs. 1114 (501-4916) ppbv; isoprene: 53.7 (19.5-244) vs. 48.7 (37.9-108) ppbv; propionaldehyde: 53.7 (32.1-82.2) vs. 42.9 (24.8-122) ppbv). Concentrations of acetone, isoprene, and propionaldehyde in breath and oxygenator outflow gas showed a parallel course with time.
Conclusions:
Acetone, isoprene, and propionaldehyde appear in breath and oxygenator outflow gas in comparable amounts. This allows for the measurement of these VOCs in a critically ill patient population via the ECMO oxygenator outflow gas without the need of ventilator circuit manipulation.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-IV
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-III
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...