Related Experiment Video
Updated: Nov 23, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Dynamic arterial elastance measured with pressure recording analytical method, and mean arterial pressure
Nora Di Tomasso1, Caterina C Lerose, Margherita Licheri
1From the Department of Anaesthesia and Intensive Care, IRCCS San Raffaele Scientific Institute (NDT, CCL, ML, ST, CV, GL, AZ, FM), Department of Anaesthesia, Mexico Hospital, San Josè, Costa Rica (LEAC) and Vita-Salute San Raffaele University, Milan, Italy (GL, AZ).
Background:
Organ perfusion is a factor of cardiac output and perfusion pressure. Recent evidence shows that dynamic arterial elastance is a reliable index of the interaction between the left ventricle and the arterial system and, in turn, of left ventricular mechanical efficiency. A practical approach to the assessment of dynamic arterial elastance at the bedside is the ratio between pulse pressure variation and stroke volume variation, which might predict the effect of a fluid challenge on the arterial pressure in patients undergoing cardiac surgery.
Objective:
To evaluate the ability of dynamic arterial elastance, measured by the pressure recording analytical method (PRAM), to predict the response of mean arterial pressure (MAP) to a fluid challenge.
Design:
Prospective observational study.
Setting:
Cardiac surgery patients in a university hospital.
Patients:
Preload-dependent (pulse pressure variation ≥13%), hypotensive (MAP ≤65 mmHg) patients, without right ventricular dysfunction, at the end of cardiac surgery.
Interventions:
A 250 ml fluid challenge infused over 3 min.
Main Outcome Measures:
A receiver-operating characteristic curve was generated to test the ability of the baseline (before fluid challenge) dynamic arterial elastance (primary endpoint) and all other haemodynamic variables (secondary endpoint) to predict MAP responsiveness (≥10% increase in MAP) after a fluid challenge.
Results:
Of 270 patients undergoing cardiac surgery, 97 (35.9%) were preload-dependent, hypotensive and received a fluid challenge. Of these 97 patients, 50 (51%) were MAP responders (≥10% increase in MAP) and 47 (48%) were MAP nonresponders (<10% increase in MAP). Baseline dynamic arterial elastance (mean ± SD) had an area under the curve of 0.64 ± 0.06 [95% confidence interval (CI), 0.53 to 0.73; P = 0.017]. A dynamic arterial elastance at least 1.07 with a grey zone ranging between 0.9 and 1.5 had 86% sensitivity (95% CI, 73 to 94) and 45% specificity (95% CI, 30 to 60) in predicting MAP increase.
Conclusion:
In a hypotensive preload-dependent cardiac surgery cohort without right ventricular dysfunction, dynamic arterial elastance measured by PRAM can predict pressure response for values greater than 1.5 or less than 0.9.
More Related Videos
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Blood Pressure