Related Experiment Video
Updated: Nov 23, 2025

Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
Noninvasive Staging of Liver Fibrosis Using 5-Minute Delayed Dual-Energy CT: Comparison with US Elastography and
Uday Kumar Marri1, Prasenjit Das1, Shalimar1
1From the Departments of Radiodiagnosis and Interventional Radiology (U.K.M., D.N.S., K.S.M.), Pathology (P.D.), Gastroenterology (Shalimar), and Biostatistics (M.K.), All India Institute of Medical Sciences, Ansari Nagar, New Delhi 110029, India.
Abstract:
Background Normalized iodine concentration (NIC) (ratio of iodine concentration of liver to that of aorta) of liver at delayed dual-energy CT (DECT) may reflect the amount of fibrosis based on the extent of iodine uptake. Purpose To stage liver fibrosis by using 5-minute delayed DECT and compare findings with those of transient elastography (TE), shear-wave elastography (SWE), and histologic examination. Materials and Methods This prospective study included patients with chronic liver disease who were scheduled to undergo multiphase abdominal CT and liver biopsy from January 2017 to September 2018. Fifty individuals being screened as renal donors comprised the control group. Study participants underwent TE, SWE, multiphasic DECT (including 5-minute delayed dual-energy scanning), and liver biopsy. Multiphasic DECT and SWE were performed in the control group. The NIC of the right lobe of the liver (RNIC) was compared with liver stiffness (LS) as measured with TE and SWE and with the METAVIR fibrosis stage (ranging from F0 to F4). Diagnostic performance was assessed by using areas under the receiver operating characteristic curve (AUCs). Results A total of 107 participants (mean age, 35 years ± 12 [standard deviation]; 57 men) and 50 control subjects (mean age, 47 years ± 11; 29 women) were evaluated. The RNIC showed strong correlation with METAVIR stage (Spearman ρ = 0.81, P < .001). The AUC for RNIC with each METAVIR stage ranged between 0.86 (95% CI: 0.76, 0.97) and 0.96 (95% CI: 0.92, 0.99). The cut-off value of RNIC was 0.24 (sensitivity: 85% [86 of 101 participants; 95% CI: 77%, 91%]; specificity: 83% [84 of 101 participants; 95% CI: 42%, 98%]) for stage F1 fibrosis and 0.29 (sensitivity: 84% [67 of 80 participants; 95% CI: 74%, 90%]; specificity: 81% [65 of 80 participants; 95% CI: 63%, 92%]) for stage F2 fibrosis. RNIC correlated well with LS as measured with TE and SWE (Spearman ρ = 0.60 and 0.64, respectively; P < .001). Conclusion Normalized iodine concentration of liver at 5-minute delayed dual-energy CT showed strong correlation with the histologic stages of liver fibrosis and good diagnostic performance in estimating liver fibrosis. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Chandarana and Shanbhogue in this issue.
More Related Videos
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
07:13Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021