Related Experiment Video
Updated: Nov 23, 2025

Comprehensive Echocardiographic Assessment of Right Ventricle Function in a Rat Model of Pulmonary Arterial Hypertension
Published on: January 20, 2023
Assessing pulmonary circulation in severe bronchopulmonary dysplasia using functional echocardiography
Arvind Sehgal1,2, Douglas Blank1,2, Calum T Roberts1,2
1Monash Newborn, Monash Children's Hospital, Monash University, Clayton, VIC., Australia.
Abstract:
Pulmonary hypertension (PH) is common in infants with severe bronchopulmonary dysplasia (BPD) and increases the risk of death. The objectives of this preliminary study were to compare responses of pulmonary circulation parameters to 100% oxygen (O2 ) and inhaled nitric oxide (iNO) in infants with BPD and PH using echocardiography. Responses between fetal growth restriction (FGR) and appropriate for gestational age infants were compared. Ten infants <28 weeks GA at birth were assessed at ≥36 weeks corrected gestation. Baseline echocardiography1 was performed which was repeated (echocardiography2) after 30 minutes of O2 . After a gap of 2-3 hours, iNO was administered for 15 minutes and echocardiography3 was performed, followed by iNO weaning. The gestation and birthweight of the cohort were 25.9 ± 1.6 weeks and 612 ± 175 g. Assessments were performed at 38.7 ± 1.4 weeks corrected gestational age. Baseline time to peak velocity: right ventricular ejection time (TPV/RVETc) increased from 0.24 ± 0.02 to 0.27 ± 0.02 (O2 , p = .01) and 0.31 ± 0.03 (iNO, p < .001), indicating a decrease in pulmonary vascular resistance [PVR]. Baseline tricuspid annular plane systolic excursion (TAPSE) increased from 8.1 ± 0.6 mm to 9.3 ± 0.7 mm (O2 , p = .01) and 10.5 ± 1.1 mm (iNO, p = .0004), indicating improved ventricular systolic performance. Percentage change for all parameters was greater with iNO. Significant correlations between cardiac performance and PVR were noted. FGR infants noted higher baseline PVR (TPV/RVETc, 0.21 ± 0.02 vs. 0.25 ± 0.01, p = .002), lower ventricular performance (TAPSE, 7 ± 1.2 mm vs. 8.6 ± 6 mm, p = .003), and lower percentage change with O2 and iNO. A reactive component of pulmonary circulation provides real-time physiological information, which could rationalize treatment decisions.
More Related Videos
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
08:21Functional Assessment of the Donor Heart During Ex Situ Perfusion: Insights from Pressure-Volume Loops and Surface Echocardiography
Published on: October 11, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History