Related Experiment Video
Updated: Nov 22, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Assessment of various continual reassessment method models for dose-escalation phase 1 oncology clinical trials:
G D James1, S Symeonides2, J Marshall3
1Medical Statistics Consultancy Ltd, London, W4 5XF, UK. g.d.r.james@gmail.com.
Background:
The continual reassessment method (CRM) identifies the maximum tolerated dose (MTD) more efficiently and identifies the true MTD more frequently compared to standard methods such as the 3 + 3 method. An initial estimate of the dose-toxicity relationship (prior skeleton) is required, and there is limited guidance on how to select this. Previously, we compared the CRM with six different skeletons to the 3 + 3 method by conducting post-hoc analysis on a phase 1 oncology study (AZD3514), each CRM model reduced the number of patients allocated to suboptimal and toxic doses. This manuscript extends this work by assessing the ability of the 3 + 3 method and the CRM with different skeletons in determining the true MTD of various "true" dose-toxicity relationships.
Methods:
One thousand studies were simulated for each "true" dose toxicity relationship considered, four were based on clinical trial data (AZD3514, AZD1208, AZD1480, AZD4877), and four were theoretical. The 3 + 3 method and 2-stage extended CRM with six skeletons were applied to identify the MTD, where the true MTD was considered as the largest dose where the probability of experiencing a dose limiting toxicity (DLT) is ≤33%.
Results:
For every true dose-toxicity relationship, the CRM selected the MTD that matched the true MTD in a higher proportion of studies compared to the 3 + 3 method. The CRM overestimated the MTD in a higher proportion of simulations compared to the 3 + 3 method. The proportion of studies where the correct MTD was selected varied considerably between skeletons. For some true dose-toxicity relationships, some skeletons identified the true MTD in a higher proportion of scenarios compared to the skeleton that matched the true dose-toxicity relationship.
Conclusion:
Through simulation, the CRM generally outperformed the 3 + 3 method for the clinical and theoretical true dose-toxicity relationships. It was observed that accurate estimates of the true skeleton do not always outperform a generic skeleton, therefore the application of wide confidence intervals may enable a generic skeleton to be used. Further work is needed to determine the optimum skeleton.
More Related Videos
Related Concept Videos
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Clinical Trials: Overview
Clinical Trials
There are four phases in a clinical trial. A phase one...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Dose Size and Dosing Frequency: Determination Methods
Dosage Regimens: Designs and Approaches

