Related Experiment Video
Updated: Nov 22, 2025

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Deformation Mechanisms of "Two-Part" Natural Adhesive in Bone Interfibrillar Nano-Interfaces
Reza Morsali1, Zhengwei Dai2, Yang Wang1
1Department of Mechanical Engineering, The University of Texas at Dallas, 800 W. Campbell Rd, Richardson, Texas 75080, United States.
Abstract:
Noncollagenous proteins at nanoscale interfaces in bone are less than 2-3% of bone content by weight, while they contribute more than 30% to fracture toughness. Major gaps in quantitative understanding of noncollagenous proteins' role in the interfibrillar interfaces, largely because of the limitation of probing their nanoscale dimension, have resulted in ongoing controversies and several outstanding hypotheses on their role and function, arguably going back to centuries ago to the original work from Galileo. Our results from the first detailed computational model of the nano-interface in the bone reveal "synergistic" deformation mechanism of a "double-part" natural glue, that is, noncollagenous osteopontin and osteocalcin at the interfibrillar interface. Specifically, through strong anchoring and formation of dynamic binding sites on mineral nanoplatelets, the nano-interface can sustain a large nonlinear deformation with ductility approaching 5000%. This large deformation results in an outstanding specific energy to failure exceeding ∼350 J/g, which is larger than the most known tough materials (such as Kevlar, spider silk, and so forth.).
More Related Videos
09:35Distinctive Capillary Action by Micro-channels in Bone-like Templates can Enhance Recruitment of Cells for Restoration of Large Bony Defect
Published on: September 11, 2015
07:14Fabrication of a Biomimetic Nano-Matrix with Janus Base Nanotubes and Fibronectin for Stem Cell Adhesion
Published on: May 10, 2020
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Cell-matrix's Response to Mechanical Forces
Anchoring junctions mechanically attach a cell to the...
Tension Response at Adherens Junctions
α-Catenin as a Mechanosensory Protein
The α-catenin of adherens junctions is an allosteric protein with three VH (vinculin...
Bone Remodeling