Purpose:
To evaluate the refractive accuracy of current intraocular lens (IOL) formulas and propose a modification in calculation of corneal power in eyes undergoing combined cataract extraction and Descemet membrane endothelial keratoplasty (DMEK).
Design:
Retrospective cohort study.
Methods:
Patients with Fuchs endothelial corneal dystrophy undergoing uncomplicated combined cataract surgery and DMEK at a single institution were included. The Hoffer Q, SRK/T, Holladay I, Barrett Universal II and Haigis formulas were compared. A modified corneal power was calculated using a thick lens equation based on anterior and posterior corneal radii and corneal thickness from Pentacam imaging. Error calculations were adjusted based on the difference in optical biometry and the modified corneal power. Mean absolute error (MAE) for each formula was compared between the corneal power modification and optical biometry corneal power.
Results:
In 86 eyes, the mean error ranged from 0.90 D for the Barrett Universal II formula to -0.10 D for the Haigis formula, with 4 of 5 formulas resulting in a mean hyperopic error. The corneal power modification resulted in a significantly lower MAE for the Hoffer Q (0.82 D), Holladay I (0.85 D), SRK/T (0.85 D) and Barrett Universal II (0.90 D) formulas compared with optical biometry corneal power for the Hoffer Q (1.02 D; p<0.005), Holladay I (0.97 D; p<0.005), SRK/T (0.93 D; p<0.01) and Barrett Universal II (1.16 D; p<0.005) formulas.
Conclusions:
All formulas except the Haigis formula resulted in a hyperopic error. The corneal power modification significantly reduced error in four out of five IOL formulas.