Related Experiment Video
Updated: Nov 22, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Respiratory Variations in Peak Peripheral Artery Velocities and Waveforms for Rapid Assessment of Fluid
Qian Zhang1, Xiu-Rong Shi2, Yi Shan3
1Department of Emergency and Critical Care Medicine, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China (mainland).
Abstract:
BACKGROUND This study aimed to assess the correlation between the variability of the end-inspiratory and end-expiratory blood flow waveform and fluid responsiveness (FR) in traumatic shock patients who underwent mechanical ventilation by evaluating peripheral arterial blood flow parameters. MATERIAL AND METHODS A cohort of 60 patients with traumatic shock requiring mechanical ventilation-controlled breathing received ultrasound examinations to assess the velocity of carotid artery (CA), femoral artery (FA) and brachial artery (BA). A rehydration test was performed in which of 250 mL of 0.9% saline was administered within 30 min between the first and second measurement of cardiac output by echocardiography. Then, all patients were divided into 2 groups, a responsive group (FR+) and a non-responsive group (FR-). The velocity of end-inspiratory and end-expiratory peripheral arterial blood flow of all patients was ultrasonically measured, and the variability were measured between end-inspiratory and end-expiratory. RESULTS The changes in the end-inspiratory and end-expiratory carotid artery blood flow velocity waveforms of the FR+ groups were significantly different from those of the FR- group (P<0.001). A statistically significant difference in ΔVmax (CA), ΔVmax (BA), and ΔVmax (FA) between these 2 groups was found (all P<0.001). The ROC curve showed that DVmax (CA) and ΔVmax (BA) were more sensitive values to predict FR compared to ΔVmax (FA). The sensitivity of ΔVmax (CA), ΔVmax (FA), and ΔVmax (BA) was 70.0%, 86.7%, and 93.3%, respectively. CONCLUSIONS The study showed that periodic velocity waveform changes in the end-inspiratory and end-expiratory peripheral arterial blood flow can be used for quick assessment of fluid responsiveness.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Acute Respiratory Failure-IV
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection

