Related Experiment Video
Updated: Nov 22, 2025

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure
Published on: April 25, 2025
Analysis of suitable private-secondary-main sewer diameters in rural areas based on cost model and hydraulic
Wenkai Li1, Tianlong Zheng2, Yingqun Ma3
1State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 18 Shuangqing Road, Haidian District, Beijing, 100085, China; SCEGC No. 12 Construction Engineering Group Company Ltd., Ankang National High-tech Industries Development Zone, Ankang, Shaanxi, 725000, China.
Abstract:
High cost of sewer systems usually restricts the sewage collection in rural areas. Many rural areas take traditional sewer scheme whose private-secondary-main sewer diameter is 110-200-300 mm without hydraulic calculation and increased the total cost of sewers. The rational utilization of small diameter sewers might contribute to sewer cost reduction. In this study, rural sewer length and cost models were established taking sewer diameter, household number, and length/width ratio of village as parameters to evaluate the cost benefits of using small diameter sewers. Hydraulic calculation of sewers was applied by Storm Water Management Model to ensure the small diameter sewers were feasible. The results indicate that household number and length/width ratio cause obvious impact on sewer length and cost. Main sewer with 200 mm diameter is suitable for the village with less than 1000 households. Using small diameter sewers can reduce the sewer cost by 6-15% compared with traditional sewer scheme and 110-110-200 might be the better scheme to rural areas because of the low cost (including construction cost and operation and maintenance cost) and high tolerance of sewage flow fluctuation. This study provided the suitable diameter of rural sewers based on cost model and hydraulic calculation which might be helpful for the application of rural sewers.
More Related Videos
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
11:53Spatial Multiobjective Optimization of Agricultural Conservation Practices using a SWAT Model and an Evolutionary Algorithm
Published on: December 9, 2012
Related Concept Videos
Design Example: Design of an Irrigation Channel
Design Example: Creating a Hydraulic Model of a Dam Spillway
Design Example: Designing a Residential Plumbing System
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Dimensional Analysis
In fluid mechanics, dimensional...
Typical Model Studies