Related Experiment Video
Updated: Nov 22, 2025

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Eye lens and thyroid gland radiation exposure for patients undergoing brain computed tomography examination
Hiba Omer1, Suhaib Alameen2, Waleed E Mahmoud2
1Department of Basic Sciences, Deanship of Preparatory Year and Supporting Studies, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 34212, Saudi Arabia.
Abstract:
This study aims to estimate the effective radiation dose and organ dose from head CT procedures. It was conducted in three main private hospitals in Khartoum State-Sudan, using Toshiba machines with 64 slices. The total number of patients included in this study was 142 patients (82 males and 60 females). The effective dose and organ dose were calculated by CT Expo software. The effective dose slightly varied among patients according to gender and age. The effective dose for female patients (5.99 mSv) was higher than that for male patients (5.84 mSv), and the pediatric dose (5.46 mSv) was lower than the adults' dose (5.94 mSv). The dose for eye lens was found lower for male patients (89.117 mSv) than the dose for female patients (94.62) mSv). According to patients' age: the dose received by the lens of the eye was much lower in pediatric (79.93 mSv) than the adults (92.41 mSv). The dose for thyroid in female patients (33.52 mSv) was higher than the male patients (28 mSv). The pediatric dose (28.34 mSv) was lower than the adults' dose (30.64 mSv). Departmental imaging protocol and lack of training among hospital staff are expected to be responsible for these variations. Therefore, this study recommends that the CT technologists be trained on suitable strategies to achieve dose optimization. Moreover, patients' doses must be monitored regularly.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET