Tiening Jin1, Junchao Zhou1, Pao Tai Lin1,2,3
1Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, USA.
Abstract:
A chip-scale mid-infrared (mid-IR) sensor was developed for hydrocarbon gas detection. The sensor consisted of amorphous Si (a-Si) optical ridge waveguides that were fabricated by complementary metal-oxide-semiconductor (CMOS) processes. The waveguide exhibited a sharp fundamental mode through λ = 2.70 to 3.50 μm. Its sensing performance was characterized by measuring methane and acetylene. From the spectral mode attenuation, the characteristic C-H absorption bands associated with methane and acetylene were found at λ = 3.29-3.33 μm and λ = 3.00-3.06 μm, respectively. In addition, real-time methane and acetylene concentration monitoring was demonstrated at λ = 3.02 and 3.32 μm. Hence, the mid-IR waveguide sensor enabled an accurate and instantaneous analysis of hydrocarbon gas mixtures.