Related Experiment Video
Updated: Nov 22, 2025

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
A randomized trial of flow-mediated dilation to prevent radial artery spasm during transradial approach
Ertugrul Zencirci1, Aycan Esen Zencirci2, Aleks Degirmencioglu3
1Department of Cardiology, Acibadem Mehmet Ali Aydinlar University School of Medicine, Istanbul, Turkey - ertuzencirci@gmail.com.
Background:
Although transradial approach has been increasingly preferred for percutaneous coronary interventions, radial artery spasm (RAS) is still one of the major disadvantages. Flow-mediated dilation (FMD) is a well-known method for assessing endothelial function through dilation. The aim of this study was to investigate the efficacy of prepuncture flow mediated dilation in preventing RAS during transradial approach.
Methods:
The present study prospectively included 222 consecutive patients who underwent transradial coronary intervention. Patients were 1:1 randomized into two groups who underwent prepuncture FMD and who did not (FMD [+] and FMD [-], respectively).
Results:
In FMD [+] group the incidence of RAS was lower (5.4% vs. 16.2%, P=0.009). Multivariate logistic regression analysis demonstrated that female sex, more than two catheter usage and transradial approach without prepuncture FMD independently predicted RAS (odds ratio [OR]=4.66, 95% confidence interval [CI]: 1.8-12.06, P=0.001, OR=5.73, 95% CI: 2.01-16.39, P=0.001, and OR=5.01, 95% CI: 1.74-14.48, P=0.003; respectively). However, access site crossover number was very low in both groups and not different between groups.
Conclusions:
Prepuncture FMD can significantly reduce RAS during transradial coronary interventions. Thus, prepuncture FMD can be used as a simple adjunctive method to prevent RAS.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Peripheral Artery Disease III: Interprofessional Care
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation