Related Experiment Video
Updated: Nov 22, 2025

A Polyaniline-based Sensor of Nucleic Acids
Published on: November 1, 2016
Pyranine Based Ion-Paired Complex as a Mechanophore in Polyurethanes
Annelore Aerts1,2, Sean J D Lugger2, Johan P A Heuts2
1DPI, P.O. Box 902AX, Eindhoven, 5600, The Netherlands.
Researchers developed a new mechanophore for polyurethane thermoplastic elastomers using ion-paired complexes. This material changes fluorescence color from yellow to blue when stretched, indicating potential for strain sensing applications.
Area of Science:
- Polymer Science
- Materials Chemistry
- Supramolecular Chemistry
Background:
- Polyurethane thermoplastic elastomers (TPUs) are versatile materials with broad applications.
- Developing novel mechanophores is crucial for creating smart materials with tunable properties.
- Ion-paired complexes offer unique opportunities for designing responsive materials.
Purpose of the Study:
- To develop a new mechanophore for TPUs based on ion-paired complexes.
- To investigate the aggregation behavior of the developed mechanophore in different media.
- To explore the mechanochromic properties of the new material.
Main Methods:
- Incorporation of 8-(2-hydroxyethoxy)pyrene-1,3,6-trisulfonate (HEPTS) as an end-capper in polyurethanes.
- Solvent polarity and concentration-dependent studies of HEPTS aggregation in solution.
- Investigation of fluorescence emission shifts upon addition of dimethylformamide (DMF) to tetrahydrofuran (THF) solutions.
- Mechanical testing of solid polymer samples to induce strain and measure stress-strain relationships.
- Correlation of fluorescence changes with applied strain and stress.
Main Results:
- HEPTS aggregates in apolar media, with aggregation dependent on concentration and solvent polarity.
- Addition of DMF to THF solutions induced a yellow-to-blue fluorescence shift, indicating aggregate dissociation.
- Stretching solid polymer samples above 1 strain and 7.5 MPa stress caused a similar fluorescence shift.
- Strain-induced dissociation of non-attached HEPTS aggregates resulted in less reproducible fluorescence changes.
Conclusions:
- A novel ion-paired complex-based mechanophore (HEPTS) was successfully developed for TPUs.
- The mechanophore exhibits concentration, solvent polarity, and strain-dependent fluorescence changes.
- The material shows potential as a fluorescent strain sensor for TPUs, with tunable mechanochromic properties.
More Related Videos
09:28Engineering Molecular Recognition with Bio-mimetic Polymers on Single Walled Carbon Nanotubes
Published on: January 10, 2017
09:04Sequence-specific and Selective Recognition of Double-stranded RNAs over Single-stranded RNAs by Chemically Modified Peptide Nucleic Acids
Published on: September 21, 2017