Related Experiment Video
Updated: Nov 22, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Minimum 10 years clinical results of an anatomical short stem with a proximal hydroxyapatite coating
Keisuke Uemura1, Hidetoshi Hamada2, Wataru Ando1
1Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan.
Objectives:
The CentPillar stem (Stryker Orthopaedics), an anatomical short stem, was designed to match the proximal femoral canal shape in both patients with normal hips and those with developmental dysplasia of the hip (DDH). The long-term outcomes of the CentPillar stem was examined herein.
Methods:
In total, 222 hips that underwent total hip arthroplasty using the CentPillar stem were analyzed. DDH was the main reason for surgery (79.3%). Implant survivorship was assessed using Kaplan-Meier analysis. For radiographic evaluation, stress shielding was assessed using the Engh classification. For functional evaluation, patients' ability to perform deep hip bending activities (sit on the floor, squat, and sit straight) was assessed.
Results:
During a median follow-up of 13.1 years, 2 stem revisions were performed (aseptic loosening and late hematogenous periprosthetic infection), and the overall cumulative implant survival rate was 99.0% at 15 years. In the radiographic evaluation, grade >3 stress shielding was found in only one hip. More than 80% of the patients were able to perform each of the three deep hip bending activities.
Conclusions:
Good fixation at the proximal part of the femur was obtained, and the implant survival rate of the CentPillar stem was excellent during a long-term follow-up.