Real-World Efficacy of the Hybrid Closed-Loop System
Chinenye O Usoh1, Crystal Paige Johnson1, Jaime L Speiser2
1Division of Endocrinology, Diabetes and Metabolism, Wake Forest University School of Medicine, NC, USA.
Background:
Hybrid closed-loop (HCL) insulin pump therapy (Medtronic 670G) is an emerging technology that is growing in use worldwide. Initial clinical trials demonstrated the effectiveness of HCL in reducing hypoglycemia and improving glucose control; however, these subjects were intensely monitored and supervised. There has been concern regarding the ability of patients to remain in auto mode. We aimed to assess HCL when used in a typical outpatient endocrine clinic.
Methods:
We initially analyzed data from 80 individuals with type 1 diabetes managed in an endocrine clinic by a single certified diabetes educator (CDE). We then included our other providers and had 230 subjects by the end of the study. Patients were either transitioned from traditional insulin pump or multiple daily insulin injection therapy (MDI) to HCL. Patients initiated to HCL pump therapy from July 2017 through February 2020 were studied. Endpoints of change in time in hypoglycemic/hyperglycemic range and time in target range were analyzed. The primary outcome was a change in percent time in the target range during manual mode compared with auto mode.
Results:
There was an 18.2% increase in average time in target range when comparing manual mode to auto mode (59.3% vs 70.1%, P < .0001). Average time in hyperglycemic range was significantly reduced by 26.7% (39.0% vs 28.6%, P < .0001) but without increasing average time in hypoglycemic range (1.7% vs 1.3%, P = 0.95).
Conclusions:
HCL was effective in reducing hyperglycemia and increasing time in the target range but did not increase hypoglycemia. These data suggest HCL will improve the metrics of glucose control.
More Related Videos
07:30In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
08:03Hybrid Cell Analysis System to Assess Structural and Contractile Changes of Human iPSC-Derived Cardiomyocytes for Preclinical Cardiac Risk Evaluation
Published on: October 20, 2022
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Hybridoma Technology
Hybridoma Selection
Commonly used fusion techniques — electroporation,...
Control Systems
At the heart...