Improving the analytical flexibility of thermal desorption in determining unknown VOC samples by using re-collection
Zhenhan Duan1, Peter Kjeldsen1, Charlotte Scheutz1
1Department of Environmental Engineering, Building 115, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark.
Abstract:
The thermal desorption (TD) technique has long suffered from the 'one-shot' problem, whereby the entire sample is consumed in a single analysis, and thus no sample remains for repeated analysis. Recent developments in TD equipment allow for the quantitative re-collection of split samples during thermal desorption, which can be utilised for archiving or immediate analysis. However, the performance of TD systems for re-collecting different volatile organic compounds (VOCs) has rarely been demonstrated. This study provides a systematic investigation into the re-collection efficiency for over 90 VOCs on a TD unit under different conditions. An analytical method was developed based on multi-sorbent tubes and TD-GC/MS, which could quantitatively measure 92 VOCs with good sensitivity (method detection limit between 0.01 and 2 ng) and precision (< 10%). Satisfactory re-collection performance (recoveries within 100% ± 20%) was found for over 70 compounds under different split modes for multiple times, and the single (outlet) split mode was preferred in this regard, in order to avoid significant uncertainties in the results. Thermal labile, polar or reactive compounds such as alcohols and ketones were generally not compatible with re-collection, as they were either lost due to thermal decomposition or formed as system artefacts. In addition, bromochloromethane should not be used as an internal standard when performing sample re-collection, since it will experience significant loss during repeated analysis and lead to overestimation for corresponding compounds. Finally, the re-collection was tested with low-concentration field samples to resolve the unexpected water problem in analysis. Although higher uncertainties were expected in the re-collected samples, the results provided good information on overall concentration variations at the sampling site, thereby instilling confidence in the results obtained from the primary analysis.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Volatilization
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Atomic Absorption Spectroscopy: Atomization Methods