Optimizing correction of coma aberration in keratoconus with a novel soft contact lens
Asaki Suzaki1, Shizuka Koh2, Naoyuki Maeda3
1Department of Applied Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan; Global R&D, Menicon Co., Ltd., Nagoya, Japan.
Purpose:
To report on a second-generation prototype contact lens (modified lens) with enhanced optics to correct coma aberration and compare its performance with that of the prototype contact lens (conventional lens) used to optimise correction of coma aberration in keratoconus (KC).
Methods:
Both lenses were designed as a set of standardised soft contact lenses (SCLs) with asymmetric powers along the posterior surface. The modified lens differs from the conventional lens in that the optical zone is decentred superiorly by 0.7 mm. The on-eye performance was compared between the SCLs and no-lens wearing in terms of manifest refraction, corrected distance visual acuity (CDVA), ocular aberrations, subjective quality of vision, and on-eye lens position relative to the pupil.
Results:
Thirty-four KC eyes were included. SCLs significantly decreased coma aberration compared to no-lens wear (none, 0.68 ± 0.27 μm; conventional lens, 0.37 ± 0.28 μm; modified lens, 0.19 ± 0.15 μm; P < 0.001), with the reduction in coma aberration being significantly greater with the modified lens than with the conventional lens (P = 0.018). No significant difference in manifest refraction or CDVA was found among the three conditions. Quality of vision was significantly better with the modified lens than with no SCL wear (P < 0.05) but no differences were found between the SCLs. The on-eye optical center position relative to the pupil was closer to the pupil centre using the modified lens than the conventional lens (P < 0.001).
Conclusion:
Optimisation of the location of the optical zone in a standardised asymmetric SCL improves correction of coma aberrations and on-eye optical centration.
More Related Videos
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
07:29Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...