Related Experiment Video
Updated: Nov 21, 2025

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Evaluation of transit time-based models in wearable central aortic blood pressure estimation
Germán Fierro1, Ricardo Armentano1, Fernando Silveira1
1Instituto de Ingeniería Eléctrica, Facultad de Ingeniería, Universidad de la República, Montevideo, Uruguay.
None:
Evidence suggests that central aortic blood pressure (CABP) may provide a more accurate prognosis of cardiovascular events than peripheral pressure. The capability of monitoring CABP in a continuous, wearable, unobtrusive way might have a significant impact on hypertension management. The purpose of this study is to experimentally explore whether a wearable device equipped with an electrocardiogram (ECG) and ballistocardiogram (BCG) acquisition system could be used to predict CABP. This is based on state-of-the-art results on the relationship between transit time extracted from these signals and CABP. Ten young, healthy volunteers participated in the study where data-sets were acquired during three hemodynamic interventions, i.e., breath-holding, Valsalva maneuver, and cold pressor. Each data-set included ECG and BCG waveforms acquired by the wearable device and a CABP assessment from a cuff-based device. A total of nine PTT-based models (PBMs) derived from pulse transit time methodology were considered. Each PBM was tested with three alternative feature times extracted from the recorded waveforms PBMs were calibrated with data-sets acquired at baseline state, which were not considered for testing the PBM estimation performance. Four of the nine tested models presented a proper agreement in estimating CABP through the acquired signals, after the calibration procedure with baseline-state data. Results in one of these promising models are the following. Mean estimation error (95% confidence interval), systolic: 0 to 1.7 mmHg, diastolic: 0.4 to 2.3 mmHg, Pearson correlation: 0.82 systolic and 0.78 diastolic (p < 0.001). The proposed methodology may lead to continuous wearable BP monitoring.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure

