Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Uncertainty estimation and statistical comparative methodology for mammography x-ray energy spectra
V Santoro-Fernandes1, J C Santos1,2, L Mariano1
1Institute of Physics, University of Sao Paulo, Sao Paulo, Brazil.
Abstract:
Numerical models are an alternative to measurements of x-ray energy spectra when validated by comparative methods that assess the similarity of experimental and calculated spectra. In this work, we compared x-ray energy spectra using several methodologies and determined the methodology with highest statistical power among them. Experiments and Monte Carlo (MC) simulations were used to generate a set of 65 experimental and simulated x-ray mammography spectra pairs typically used in mammography applications. They were generated using Tungsten and Molybdenum targets and Molybdenum and Rhodium filters. The x-ray beams were transmitted through breast tissue equivalent material (bTEM) plates with different glandularities and thicknesses, and the transmitted beam was detected using solid-state x-ray spectrometry with a Cadmium Telluride (CdTe) diode. The MC simulations used the PENELOPE code. Additional uncertainties, beyond that from counting, were propagated using the MC method. Quantitative comparative methods based on the [Formula: see text] statistics, the first and second half-value layers, the mean energy, the effective energy, and the non-parametric u-test were applied and their specificity (true negative rate) was assessed. The polyenergetic normalized glandular dose (DgNp) to a 6 cm breast of 50/50 glandularity was derived from the spectra. In this work, the [Formula: see text] statistics attained the highest score; therefore, it is the most indicated metric for the x-ray energy spectra comparative evaluations. The contribution of the additional uncertainties was important, being responsible for up to 98% of the spectra total uncertainty and shifting the mean of the evaluated [Formula: see text] to 1.2(1), compatible with its expected value. The use of non-parametric test is discouraged by our results, since it failed to distinguish spectra pairs that resulted in up to 72% discrepant DgNp.
Related Concept Videos
Uncertainty: Overview
Propagation of Uncertainty from Systematic Error
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging