Time to ventilation and success rate of airway devices in microgravity: A randomized crossover manikin-trial using an
Tobias Warnecke1, Lisa Dauth2, Anton Ahlbäck3,4
1Department of Anaesthesiology, Critical Care, Emergency Medicine and Pain Therapy, Hospital of Oldenburg, Medical Campus University of Oldenburg, Oldenburg, Germany.
Background:
Medical support for space exploration missions must prepare for severe medical events in conditions of microgravity. A key component to managing these events is techniques of airway management. The aim of the present trial is to compare airway management devices in simulated microgravity.
Methods:
In this randomized cross-over trial (RCT), four different devices were compared under simulated microgravity conditions utilizing a neutrally buoyant free-floating underwater manikin and poolside in normal gravity (control group). The primary endpoint was the successful placement of the airway device. The secondary endpoints were the number of attempts and the duration of each attempt.
Results:
A total of 20 participants performed placement of each device in both gravity conditions in an Airway mannequin. The fastest time to initial ventilation in simulated microgravity was possible with the laryngeal tube (18.9 ± 8 seconds) followed by laryngeal mask (20.1 ± 9 seconds). The I-gel® supraglottic airway device required substantially more time for successful insertion in simulated microgravity (35.4 ± 25 seconds) as did endotracheal tube intubation by direct laryngoscopy (70.4 ± 35 seconds). Simulated microgravity conditions prolonged time to initial ventilation by 3.3 seconds (LM), 3.9 seconds (LT), 19.9 seconds (I-gel) and 43.1 seconds (endotracheal intubation, ETI) when compared to poolside attempts in normogravity.
Conclusion:
In simulated microgravity conditions, use of the laryngeal tube or laryngeal mask provided the quickest time to initial ventilation, without deliberate tethering of the mannequin and rescuer to a fixed surface. Endotracheal intubation required significantly longer procedure times and, thus, was considered insufficient for clinical use in microgravity.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...