Related Experiment Video
Updated: Nov 21, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
NCINM: organ dose calculator for patients undergoing nuclear medicine procedures
Daphnée Villoing1, Thomas A Cuthbert1,2, Cari M Kitahara1
1Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, United States of America.
Abstract:
Nuclear medicine is the second largest source of medical radiation exposure to the general population after computed tomography imaging. Informed decisions regarding the use of nuclear medicine procedures require a better understanding of the magnitude of radiation dose and associated health risks. However, existing model-based organ dose estimation tools rely on simplified human anatomy models or commercial programs. Therefore, we developed a publicly-available dose calculation tool based on more sophisticated human anatomy models. We calculated a comprehensive library of photon and electron specific absorbed fractions (SAF) for multiple combinations of source and target regions within a series of pediatric and adult computational human phantoms matching the International Commission on Radiological Protection (ICRP)'s reference data, combined with a Monte Carlo radiation transport code. Then, we derived a library of S values from these SAFs and the nuclear decay data from ICRP Publication 107. Finally, we created a graphical user interface, named National Cancer Institute Dosimetry System for Nuclear Medicine (NCINM), to facilitate the dosimetry process. Approximately 13 million S values were derived from 2 million SAFs computed in this work. Comprehensive comparisons were conducted at different steps of the dosimetry chain with data available in software OLINDA/EXM 1.0 and IDAC 2.1. For instance, median ratios of photon self-absorption SAFs available from OLINDA/EXM 1.0 and IDAC 2.1 to those calculated in this study were 1.3 (interquartile range = 1.1-1.6) and 1.0 (interquartile range = 0.98-1.0), respectively. SAF differences between NCINM and OLINDA/EXM 1.0 were explained by the large inter-phantom anatomical variability. Our results illustrate the importance of realistic human anatomy models for use in dosimetry software. More phantoms and radionuclides, as well as a biokinetic module, will soon be added. Applications of the NCINM program include computation of absorbed doses for use in radiation epidemiologic studies and patient dose monitoring in nuclear medicine.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Isotopes and Radioisotopes
An isotope containing...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

