Characterization and comparison of imaging contrast enhancement with PEG-functionalized gold nanoparticles in kV cone
Tara Gray1, Nema Bassiri2, Shaquan David1
1The University of Texas at San Antonio, Department of Physics and Astronomy, San Antonio, TX 78249, United States of America.
Abstract:
The purpose of this study is to define a simplified method to accurately predict and characterize kV cone beam computed tomography (kV CBCT) and computed tomography (CT) image contrast enhancement from gold nanoparticles (GNPs). Parameters of the kV CBCT of a Varian Novalis Tx linear accelerator and of a GE LightSpeed 4 Big Bore CT machine were modeled using the MCNP 6.2 Monte Carlo code. A 0.25 × 0.25 cm2 source, defined with a 100 kVp energy spectrum with appropriate filtration, was implemented in the MCNP6.2 model for kV CBCT, which also contained x- and y-blades and a full bowtie filter. A 1 cm3 cube of GNP solution (modeled as a mass percentage of gold in water) was placed 100 cm below the source. For the CT-simulator model, a source was defined with energy spectra for 80 and 140 kVp x-rays with appropriate filtration and angular spectrum. A 1 cm3 GNP solution was modeled as before and a detector was placed 40 cm below that. Attenuation coefficients of four GNP solutions were computed and Hounsfield unit (HU) values were calculated. The computed HU values were compared against experimentally measured values obtained by scanning batches of GNPs of various sizes and concentrations using a GE LightSpeed 4 Big Bore CT scanner at 80 kVp and 140 kVp energies, as well as the kV CBCT capability of a Varian Novalis Tx linear accelerator. HU analysis was carried out using Velocity Medical Solutions clinical CT image analysis software. The MCNP calculated HU values matched the measured values to within ± 5%. Image contrast enhancement analysis showed a total increase in HU of up to 223. The sample having the highest gold mass percentage tested showed the greatest increase in HU number compared to water.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging