Related Experiment Video
Updated: Nov 21, 2025

Author Spotlight: Integrating High-Resolution Intravital Imaging and MRI to Enhance Stereotactic Body Radiation Therapy Planning
Published on: April 12, 2024
A comparative study of methods for determining Intravoxel incoherent motion parameters in cervix cancer
Xue Wang1, Jiao Song1, Shengfa Zhou1
1Department of Radiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, 109 Xueyuanxi Road, Wenzhou, 325027, China.
Background:
To compare different fitting methods for determining IVIM (Intravoxel Incoherent Motion) parameters and to determine whether the use of different IVIM fitting methods would affect differentiation of cervix cancer from normal cervix tissue.
Methods:
Diffusion-weighted echo-planar imaging of 30 subjects was performed on a 3.0 T scanner with b-values of 0, 30, 100, 200, 400, 1000 s/mm2. IVIM parameters were estimated using the segmented (two-step) fitting method and by simultaneous fitting of a bi-exponential function. Segmented fitting was performed using two different cut-off b-values (100 and 200 s/mm2) to study possible variations due to the choice of cut-off. Friedman's test and Student's t-test were respectively used to compare IVIM parameters derived from different methods, and between cancer and normal tissues.
Results:
No significant difference was found between IVIM parameters derived from the segmented method with b-value cutoff of 200 s/mm2 and the simultaneous fitting method (P>0.05). Tissue diffusivity (D) and perfusion fraction (f) were significantly lower in cervix cancer than normal tissue (P< 0.05).
Conclusions:
IVIM parameters derived using fitting methods with small cutoff b-values could be different, however, the segmented method with b-value cutoff of 200 s/mm2 are consistent with the simultaneous fitting method and both can be used to differentiate between cervix cancer and normal tissue.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System V: CT