Related Experiment Video
Updated: Nov 21, 2025

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
Force changes associated with differential activation of en-masse retraction and/or intrusion with clear aligners
1Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.
Objective:
To investigate the three-dimensional forces created by clear aligners on mandibular teeth during differential activation with en-masse retraction and/or intrusion in vitro.
Methods:
Six sets of clear aligners were designed for differential en-masse retraction and/or intrusion procedures in a first premolar extraction model. Group A0 was a control group with no activation. Groups A1-5 underwent different degrees of retractions and/or intrusions. Each group consisted of 10 aligners. Aligner forces were measured on a multi-axis force/ torque transducer measurement system in real-time.
Results:
In the en-masse retraction groups (A1 and A2), lingual and extrusive forces were observed on the incisors; the canines mainly received distal forces; intrusive forces were seen on the second premolars; and the molars received mesial forces. In the enmasse retraction and intrusion groups (A3, A4, and A5), incisors also received lingual and extrusive forces; canines received distal and intrusive forces; mesial and extrusive forces were seen on the second premolars; and the second molars received distal and intrusive forces. The vertical forces on the incisors did not differ significantly among groups A1, A3, and A5. However, the vertical forces on the second premolars reversed from intrusion in group A1 to extrusion in groups A3 and A5.
Conclusions:
With clear aligners, the "bowing effect" is seen during en-masse anterior teeth retraction and can be partially relieved by performing en-masse retraction accompanied by anterior teeth intrusion. Vertical control of incisors remained unsolved during en-masse retraction, even when intrusive activation was added to the anterior teeth.
More Related Videos
Related Concept Videos
Cell-matrix's Response to Mechanical Forces
Anchoring junctions mechanically attach a cell to the...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Tension Response at Adherens Junctions
α-Catenin as a Mechanosensory Protein
The α-catenin of adherens junctions is an allosteric protein with three VH (vinculin...
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...

