Related Experiment Video
Updated: Nov 21, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Evaluation of transcutaneous carbon dioxide and saturation monitoring during fiberoptic bronchoscopy
Merve Yumrukuz Şenel1, Hikmet Fırat2, Emine Bahar Kurt2
1Clinic of Chest Diseases, Balıkesir State Hospital, Balıkesir, Turkey.
Introduction:
The aim of the study was to assess the effects of interventions during bronchoscopy on ventilation and determine the risk factors for hypoventilation related to both interventions and patients' demographical and clinical characteristics.
Materials And Methods:
A total of 74 patients who underwent fiberoptic bronchoscopy (FOB) were included in the study. Oxygen saturation (SpO2) and partial carbon dioxide pressure (PCO2) were measured transcutaneously (TcSO2 and TcPCO2) using a sensor consisting of a probe placed on the earlobe. The demographic characteristics and basal, mean, peak and minimum values of TcSO2 and TcPCO2 during FOB were retrospectively analyzed and assessed in terms of the risk factors for hypoventilation.
Result:
During the procedure, the device automatically recorded the TcSO2 and TcPCO2 values. The mean TcPCO2 level was 37.09 ± 5.6 (27.1-60.6) mmHg. The mean increase in the TcPCO2 level from baseline was 3.25 ± 2.12 mmHg. The mean TcSO2 measurement was 95.9 ± 2.27 (80-100%). The measured mean and peak TcPCO2 values were significantly higher in men. In the whole group, the patients with a history of smoking more than 20 packyears also had significantly higher TcPCO2 values compared to the nonsmokers and light smokers. In the patients with endobronchial lesions, the decrease in the TcSO2 level was higher during FOB (p= 0.03), and the mean difference between the lowest and mean TcSO2 levels was significantly greater (6.2 vs 4.55%, p= 0.03).
Conclusions:
Changes in ventilation during FOB have multifactorial causes. The best indicator of ventilation is PCO2, and monitorization of PCO2 is very important in detecting hypoventilation. In this study, we determined some risk factors for hypoventilation in order to predict ventilation problems in patients planned to undergo FOB. We recommend that in male patients with endobronchial lesions, those with a longer smoking history, and those with a longer duration of FOB, SpO2 should be monitored together with PCO2.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...