Related Experiment Video
Updated: Nov 21, 2025

Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
[Ablation of a para-Hisian accessory pathway with high-power short-duration]
Christian Spies1, Martin Neef2
1Klinik und Poliklinik für Kardiologie, Universitätsklinikum Leipzig, Liebigstraße 20, 04103, Leipzig, Deutschland. christian.spies@medizin.uni-leipzig.de.
Abstract:
We report the case of a 30-year-old man who presented to our emergency department with rapid heart beat and a narrow complex tachycardia at a rate of 215 beats per minute. With the working diagnosis of Wolf-Parkinson-White syndrome with paroxysmal orthodromic tachycardias, we performed an electrophysiological study. In this examination, there was a para-Hisian accessory pathway with very fast, prognostically relevant conduction properties. In order to protect the His bundle that is located deeper in the tissue and to avoid a deeper lesion, we decided to use high-power short-duration ablation. This method, which was recently used in three-dimensional-controlled radiofrequency ablation of pulmonary veins, causes more superficial lesions in order to protect the surrounding tissue. In our case, using the high-power short-duration method, we were able to successfully ablate the para-Hisian accessory pathway, while protecting the His bundle near the ablation site.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013