Related Experiment Video
Updated: Nov 21, 2025

Methods to Quantify Pharmacologically Induced Alterations in Motor Function in Human Incomplete SCI
Published on: April 18, 2011
Reliability of isokinetic tests of velocity- and contraction intensity-dependent plantar flexor mechanical properties
Matheus D Pinto1, Cody J Wilson1, Anthony D Kay2
1Centre for Exercise and Sports Science Research (CESSR), School of Medical and Health Sciences, Edith Cowan University, Perth, WA, Australia.
Abstract:
"Flexibility" tests are traditionally performed voluntarily relaxed by rotating a joint slowly; however, functional activities are performed rapidly with voluntary/reflexive muscle activity. Here, we describe the reliabilities and differences in maximum ankle range of motion (ROMmax ) and plantar flexor mechanical properties at several velocities and levels of voluntary force from a new test protocol on a commercially available dynamometer. Fifteen participants had their ankle joint dorsiflexed at 5, 30, and 60° s-1 in two conditions: voluntarily relaxed and while producing 40% and 60% of maximal eccentric torque. Commonly reported variables describing ROMmax and resistance to stretch were subsequently calculated from torque and angle data. Absolute (coefficient of variation (CV%) and typical error) and relative (ICC2,1 ) reliabilities were determined across two testing days (≥72 h). ROMmax relative reliability was good in voluntarily relaxed tests at 30 and 60° s-1 and moderate at 5° s-1 , despite CVs ≤ 10% for all velocities. Tests performed with voluntary muscle activity were only reliable when performed at 5° s-1 , and ROMmax reliability was moderate and CV ≤ 8%. For most variables, the rank order of participants differed between the slow-velocity, relaxed test, and those performed at faster speeds or with voluntary activation, indicating different information. A person's flexibility status during voluntarily relaxed fast or active stretches tended to differ from their status in the traditional voluntarily relaxed, slow-velocity test. Thus, "flexibility" tests should be completed under conditions of different stretch velocity and levels of muscle force production, and clinicians and researchers should consider the slightly larger between-day variability from slow-velocity voluntarily relaxed tests.
More Related Videos
02:15Predictive Measurement for Windlass Change in Length and Selected Treatment Outcomes in Chronic Plantar Fasciitis
Published on: March 1, 2024
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019