Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Evaluating the efficiency of three methods to clean and disinfect screw- and cement-retained prostheses
Lina Yin1, Yibo Zhu2, Huajie Yu3
1Registered nurse, Fourth Clinical Division, Peking University School and Hospital of Stomatology, Beijing, PR China.
Statement Of Problem:
Screw- and cement-retained prostheses (SCRPs) may be contaminated during fabrication in a dental laboratory, leading to mechanical and biological complications related to the implant treatment. Studies that explored methods to efficiently and conveniently clean and disinfect SCRPs are sparse.
Purpose:
The purpose of this clinical study was to compare the efficiency of 3 methods to remove contaminants and microorganisms present on the surface of an SCRP.
Material And Methods:
Forty-eight 1-unit SCRPs fabricated in a dental laboratory were randomly divided into 3 groups: wiping, soaking, or ultrasonic cleaning. The presence of contaminants was determined by scanning electron microscopy, and microbial cells were cultured before and after treatment. Bacterial colony-forming units (CFUs) on the surface of the SCRPs and contamination density at the implant-abutment interface and emergence profile area were assessed. Statistical tests including ANCOVA were used to compare the efficiency of different methods before and after treatment (α=.05).
Results:
Significant differences in contamination density were noted during the treatment at the implant-abutment interface and at the emergence profile area in the 3 groups (P<.05), but no significant differences were observed in the number of CFUs (P>.05). There were significant differences among the 3 methods for cleaning efficiency both at the implant-abutment interface (P=.023) and the emergence profile area (P=.038). At the implant-abutment interface, the contamination density after treatment was lower in the ultrasonic cleaning group than that in the soaking group (P=.007), whereas at the emergence profile area, the contamination density after treatment was lower in the ultrasonic cleaning group than that in the wiping group (P=.019) and the soaking group (P=.048).
Conclusions:
All 3 treatment methods reduced contaminants on the SCRP surface, but ultrasonic cleaning yielded the most favorable results. However, none of the methods provided additional disinfection for SCRPs previously disinfected by ozone and UV in a dental laboratory.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Hand hygiene
Hand washing...