A Real-Time Blood Flow Measurement Device for Patients with Peripheral Artery Disease
Mahmood K Razavi1, D Preston T Flanigan1, Sean M White2
1Vascular & Interventional Specialists of Orange County, 1140 W. La Veta Ave., no. 850, Orange, CA 92868.
Purpose:
To evaluate the feasibility of a new optical device that measures peripheral blood flow as a diagnostic and monitoring tool for patients with peripheral artery disease (PAD).
Materials And Methods:
In this prospective study, 167 limbs of 90 patients (mean age, 76 y; 53% men) with suspected PAD were evaluated with the FlowMet device, which uses a new type of dynamic light-scattering technology to assess blood flow in real time. Measurements of magnitude and phasicity of blood flow were combined into a single-value flow-waveform score and compared vs ankle-brachial index (ABI), toe-brachial index (TBI), and clinical presentation of patients per Rutherford category (RC). Receiver operating characteristic curves were constructed to predict RC. Area under the curve (AUC), sensitivity, and specificity were compared among flow-waveform score, ABI, and TBI.
Results:
Qualitatively, the FlowMet waveforms were analogous to Doppler velocity measurements, and degradation of waveform phasicity and amplitude were observed with increasing PAD severity. Quantitatively, the flow, waveform, and composite flow-waveform scores decreased significantly with decreasing TBI. In predicting RC ≥ 4, the flow-waveform score (AUC = 0.83) showed a linear decrease with worsening patient symptoms and power comparable to that of TBI (AUC = 0.82) and better than that of ABI (AUC = 0.71). Optimal sensitivity and specificity pairs were found to be 56%/83%, 72%/81%, and 89%/74% for ABI, TBI, and flow-waveform score, respectively.
Conclusions:
The technology tested in this pilot study showed a high predictive value for diagnosis of critical limb ischemia. The device showed promise as a diagnostic tool capable of providing clinical feedback in real time.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:20A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
Published on: August 30, 2017
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Peripheral Artery Disease I: Introduction