Objective:
The aim of the work was to evaluate STE feasibility as DSE visualization method and its accuracy compared to coronary angiography (CAG) in the patients with moderate-tohigh coronary arteries disease (CAD) risk.
Patients And Methods:
Materials and methods: We prospectively examined 140 pts (84 (60.0%) men) with suspected CAD in order to verify diagnosis and evaluate myocardial viability and coronary reserve.
Results:
Results: Mean LV EF was 54.4±15.8%. All pts had normal BP and HR during the test. There were no significant hemodynamics alterations during the test. There were no significant complications during DSE - 15 (12.9%) cases of different relatively low-grade supraventricular and ventricular arrhythmia, mainly transitory without interventions. There were 116 (82.9%) positive DSE results, of which 2 (1.72%) were false-positive. In 2 (8.3%) pts with negative DSE results CAG revealed 1-vessel insignificant (50 - 70%) lesions with developed collaterals (false-negative results). According to DSE and CAG results, 96 (82.3%) pts underwent revascularization interventions - 86 (89.6%) PCI's and (10.4%) CABG surgeries. Sensitivity and specificity of DSE with STE for primary CAD diagnosis according to "golden standard" CAG results were 98.3% and 91.7%, respectively, with identical positive and negative predictive value and very high method overall accuracy (AUC = 0.98) and OR = 627.0 (p<0.0001). Sensitivity and specificity of DSE with STE for defining indications for intervention and revascularization were 97.9% and 91.7%, respectively, with high overall accuracy (AUC = 0.95; OR = 564.0, p<0.0001). Combined quantification of ΔGLS and ΔWMSI for primary CAD diagnosis showed significantly lower sensitivity 86.2% (р=0.0002) and specificity 80.4% (р=0.0064) with significantly lower integral method accuracy (AUC 0.83, р<0.0001).
Conclusion:
Conclusions: DSE with STE as a visualization method is a safe and optimal method for ischemia diagnosis and myocardial viability and coronary reserve evaluation in the pts with CAD suspicion. Given the lower ΔGLS and ΔWMSI accuracy compared to integral DSE with STE result evaluation, as well as frequent GLS growth in significant amount of patients with definite positive test result, authors recommend evaluating integral test result rather than strain value.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
07:13Author Spotlight: Advancing Neonatal Cardiac Diagnostics with Echocardiography-Derived Blood Speckle Imaging
Published on: December 22, 2023
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT