Related Experiment Video
Updated: Nov 21, 2025

Study of Short Peptide Adsorption on Solution Dispersed Inorganic Nanoparticles Using Depletion Method
Published on: April 11, 2020
Characterization of Drug-Polymer Adsorption Isotherms in Body-on-a-Chip Systems by Inverse Liquid-Solid
Mark T Schnepper1, Jeff Roles2, James J Hickman1,2
1NanoScience Technology Center, University of Central Florida, 12424 Research Parkway, Suite 400, Orlando, Florida 32826, United States.
Abstract:
Body-on-a-chip and human-on-a-chip systems are currently being used to augment and could eventually replace animal models in drug discovery and basic biological research. However, hydrophobic molecules, especially therapeutic compounds, tend to adsorb to the polymer materials used to create these microfluidic platforms, which may distort the dose-response curves that feed into pharmacokinetic/pharmacodynamic (PK/PD) models, which translate preclinical data into predictions of clinical outcomes. Inverse liquid-solid chromatography paired with a numerical optimization based on the Langmuir model of adsorption was used to characterize the adsorption isotherm parameters of drugs to polydimethylsiloxane (PDMS) and polymethylmethacrylate (PMMA), polymers commonly used in these platforms. The adsorption isotherms were then compared against concentration measurements of drugs recirculated in these platforms. This research further illustrates the point that by quantifying drug or drug candidate interactions before system dosing and including this data in the PK/PD models, then polymers used in these platforms need not be limited to "less-adsorbing" materials.
More Related Videos
14:43Microfluidic On-chip Capture-cycloaddition Reaction to Reversibly Immobilize Small Molecules or Multi-component Structures for Biosensor Applications
Published on: September 23, 2013
06:08Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
Related Concept Videos
Analyte Adsorption and Distribution
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Affinity Chromatography
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...