Related Experiment Video

Updated: Nov 21, 2025

Computer-based Multitaper Spectrogram Program for Electroencephalographic Data
04:13

Computer-based Multitaper Spectrogram Program for Electroencephalographic Data

Published on: November 13, 2019

12.6K

Role of electroencephalogram oscillations and the spectrogram in monitoring anaesthesia

M Cindy Kim1, G L Fricchione2, E N Brown1,3

  • 1Department of Anaesthesia, Benson-Henry Institute for Mind Body Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.

BJA Education
|January 18, 2021
PubMed
Abstract

No abstract available in PubMed .

More Related Videos

Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
14:52

Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers

Published on: January 13, 2018

11.2K
Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates
05:58

Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates

Published on: September 6, 2017

40.0K

Related Experiment Videos

Last Updated: Nov 21, 2025

Computer-based Multitaper Spectrogram Program for Electroencephalographic Data
04:13

Computer-based Multitaper Spectrogram Program for Electroencephalographic Data

Published on: November 13, 2019

12.6K
Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
14:52

Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers

Published on: January 13, 2018

11.2K
Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates
05:58

Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates

Published on: September 6, 2017

40.0K

Related Concept Videos

Brain Waves01:23

Brain Waves

2.9K
Brain waves are electrical signals generated by the neurons in the brain, which are regularly monitored to measure mental activities. Brain waves and their frequency ranges can be measured using an electroencephalogram or EEG. There are four main types of brain waves, each with distinct characteristics:
2.9K
Stages of General Anesthesia01:22

Stages of General Anesthesia

1.1K
Various sedation levels offer significant advantages in facilitating procedural interventions for patients undergoing medical or invasive surgical procedures. These levels span from anxiolysis to general anesthesia, providing a spectrum of sedative effects to cater to specific patient needs. Anxiolysis reduces anxiety and is achieved through minimal sedation, enabling patients to remain awake and responsive while feeling more at ease during the procedure. This level can benefit minor...
1.1K

Articles linked to this work by shared authors, journal, and citation graph.

Neuropsychiatric phenotypes of anti-NMDAR encephalitis: a prospective study.

Psychological medicine·2022

Corrigendum to 'Role of electroencephalogram oscillations and the spectrogram in monitoring anaesthesia' [BJA Education 20 (2020) 166-172].

BJA education·2021

The neuroinflammatory component of negative affect in patients with chronic pain.

Molecular psychiatry·2019

Electroencephalographic markers of brain development during sevoflurane anaesthesia in children up to 3 years old.

British journal of anaesthesia·2018

On compression and damage evolution in two thermoplastics.

Proceedings. Mathematical, physical, and engineering sciences·2017

Age-dependency of sevoflurane-induced electroencephalogram dynamics in children.

British journal of anaesthesia·2015

Erratum to 'Update on the perioperative management of diabetes mellitus' [BJA Education 24 (2024) 261-269].

BJA education·2026

Corrigendum to 'Clinical presentation and management of right ventricular dysfunction' [BJA Education 19 (2019) 183-190].

BJA education·2026

Environmental benefits of reintroducing reusable drapes and gowns in the operating room.

BJS open·2026

Colorimetric sensor array based on pH-modulated inhibitory effect of a single nanozyme'activity for antioxidant recognition.

Talanta·2026

Comparison of Gentleness and Reapplication Between Two Pulse Oximetry Probes in Healthy Adults in a Laboratory Setting.

Medical devices (Auckland, N.Z.)·2026

Clinical applicable skin-interfaced thermal guiding sensor for warning perioperative abnormalities in core body temperature and blood perfusion rate.

Nature communications·2026

Comparative outcomes of delta-on-delta and delta-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a nationwide cohort study.

Archives of orthopaedic and trauma surgery·2026

EARL-based quantitative evaluation of administered activity reduction for [68Ga]Ga-DOTATOC PET/CT on a 32-cm axial FOV digital BGO system: Phantom analysis and retrospective list-mode clinical assessment.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
See all related articles
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies
Jove
Visualize
Contact Us