Related Experiment Video
Updated: Nov 21, 2025

Transdermal Measurement of Glomerular Filtration Rate in Mechanically Ventilated Piglets
Published on: September 13, 2022
Use of infrared thermography to noninvasively assess neonatal piglet temperature
Oceane Schmitt1,2,3, Keelin O'Driscoll1
1Pig Development Department, Teagasc Animal and Grassland Research and Innovation Centre, Fermoy, Ireland.
Abstract:
Hypothermia is risk factor for piglet neonatal mortality, especially for low birth weight piglets. Piglets with intrauterine growth retardation (IUGR) also have a higher mortality risk at birth. This study aimed to validate infrared thermography (IRT) as an alternative to rectal temperature (RT) to measure piglet temperature in the hour postpartum, and to identify piglets with thermoregulation difficulties. At birth (6.3 ± 0.35 min postpartum), 67 piglets were dried, weighed, scored for growth retardation (IUGR; 0-3), and isolated in a plastic box where IRT images were taken, followed by RT. Piglets were then returned to the farrowing pen, and the process repeated at 15, 30, and 60 min postpartum. Piglets were ranked according to their weight (quartiles: 0.57-1.27 kg, 1.27-1.5 kg, 1.5-1.74 kg, 1.74-2.44 kg). Temperatures (ear base and tip; minimum, maximum and average of back) were extracted from IRT images (Thermacam Researcher Pro 2.0). Pearson correlations between temperature measures were calculated, and the effect of time, IUGR score, and weight were included in linear mixed models (SAS 9.4). RT was correlated with all IRT data across time points (P < 0.05); correlations were strongest with the ear base, and weakest with the ear tip and minimum back temperature. Both IUGR score and weight rank affected ear base (P < 0.05) and RTs (P < 0.05). The lightest piglets, and piglets with severe IUGR had the lowest temperature, relative to their counterparts. Indeed, differences between all weights categories were significant for RT. Piglets with the lowest weight (0.27-1.27 kg) had lower ear base temperatures than piglets in the third quartile (1.5-1.74 kg; 35.2 ± 0.36 °C vs. 36.5 ± 0.35 °C, t 64.9 = -4.51, P < 0.001) and the heaviest piglets (1.74-2.44 kg; 35.2 ± 0.36 °C vs. 36.4 ± 0.36 °C, t 70.4 = -3.97, P < 0.005). Overall, piglets with severe IUGR (score 3) had a lower RT than normal piglets (score 0; 35.8 ± 0.46 °C vs. 37.2 ± 0.42 °C, t 43.1 = 3.16, P < 0.05) and piglets with mild IUGR (score 1; 35.8 ± 0.46 °C vs. 37.1 ± 0.40 °C, t 45.3 = 2.92, P < 0.05); and they also had lower temperature at the base of the ear than normal piglets (35.1 ± 0.42 °C vs. 36.3 ± 0.36 °C, t 63.1 = 3.01, P < 0.05). These results confirmed that IRT is an interesting noninvasive tool for assessing neonatal piglets' thermoregulatory abilities and could be used in research investigating successful interventions for piglets at risk of hypothermia.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

