Three years' experience of quality monitoring program on pre-analytical errors in china
Fengfeng Kang1, Weixing Li1, Xiaohua Xia1
1Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Zhejiang Center for Clinical Laboratories, Hangzhou, China.
Background:
Various errors in the procedure of specimen collection have been reported as the primary causes of pre-analytical errors. The aim of this study was to monitor and assess the reasons and frequencies of rejected samples in China.
Methods:
A pre-analytical external quality assessment (EQA) scheme involving six quality indicators (QIs) was conducted from 2017 to 2019. Rejection rate was calculated for each QI. The difference of the rejection rates over the time was checked by Chi-square test. Furthermore, the 25th, 50th, and 75th percentiles of the results from total laboratories each year were calculated as optimum, desirable, and minimum level of performance specifications.
Results:
In total, 423 laboratories submitted data continuously for six EQA rounds. The overall rejection rates were 0.2042%, 0.1709%, 0.1942%, 0.1689%, 0.1593%, and 0.1491%, respectively. The most common error was sample hemolysed (0.0514%-0.0635%), and the least one was sample not received (0.0008%-0.0014%). A significant reduction in percentages was observed for all QIs. For biochemistry and immunology, hemolysis accounted for more than half of the rejection causes, while for hematology, the primary cause shifted from incorrect fill level to sample clotted. The quality specifications had improved over time, except for the optimum level.
Conclusion:
The significant reduction in error rates on sample rejection we observed suggested that laboratories should pay more attention to the standardized specimen collection. We also provide a benchmark for QIs performance specification to help laboratories increase awareness about the critical aspects in the need of improvement actions.
Related Concept Videos
Quality Assurance
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Data Validation
Key parameters for method validation include:
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Errors occurring during blood pressure monitoring
Several factors...