Impairments in Blood Pressure Regulation and Cardiac Baroreceptor Sensitivity Among Patients With Heart Failure
Christine Sailer1, Hannah Edelmann2, Cullen Buchanan3
1Department of Medicine-Cardiology (C.S., G.C., M.B., A.V.A., E.W., W.K.C.), University of Colorado Anschutz Medical Campus, Aurora.
Background:
Continuous-flow (CF) left ventricular assist devices (LVADs) improve outcomes for patients with advanced heart failure (HF). However, the lack of a physiological pulse predisposes to side-effects including uncontrolled blood pressure (BP), and there are little data regarding the impact of CF-LVADs on BP regulation.
Methods:
Twelve patients (10 males, 60±11 years) with advanced heart failure completed hemodynamic assessment 2.7±4.1 months before, and 4.3±1.3 months following CF-LVAD implantation. Heart rate and systolic BP via arterial catheterization were monitored during Valsalva maneuver, spontaneous breathing, and a 0.05 Hz repetitive squat-stand maneuver to characterize cardiac baroreceptor sensitivity. Plasma norepinephrine levels were assessed during head-up tilt at supine, 30o and 60o. Heart rate and BP were monitored during cardiopulmonary exercise testing.
Results:
Cardiac baroreceptor sensitivity, determined by Valsalva as well as Fourier transformation and transfer function gain of Heart rate and systolic BP during spontaneous breathing and squat-stand maneuver, was impaired before and following LVAD implantation. Norepinephrine levels were markedly elevated pre-LVAD and improved-but remained elevated post-LVAD (supine norepinephrine pre-LVAD versus post-LVAD: 654±437 versus 323±164 pg/mL). BP increased during cardiopulmonary exercise testing post-LVAD, but the magnitude of change was modest and comparable to the changes observed during the pre-LVAD cardiopulmonary exercise testing.
Conclusions:
Among patients with advanced heart failure with reduced ejection fraction, CF-LVAD implantation is associated with modest improvements in autonomic tone, but persistent reductions in cardiac baroreceptor sensitivity. Exercise-induced increases in BP are blunted. These findings shed new light on mechanisms for adverse events such as stroke, and persistent reductions in functional capacity, among patients supported by CF-LVADs. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03078972.
More Related Videos
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Heart Failure II: Pathophysiology
Heart Failure Drugs: β-Blockers
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Pathophysiology of Heart Failure
Heart Failure V: Medical Management
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...