Saline as an Alternative to Radio-Contrast for Optical Coherence Tomography-Guided Percutaneous Coronary
Ankush Gupta1, Sanya Chhikara2, Rajesh Vijayvergiya3
1Professor of Medicine & Interventional Cardiologist, Head of Department (Cardiology), Military Hospital Jaipur, Rajasthan 302016, India.
Objectives:
To do a quantitative comparison of saline and contrast Frequency domain optical coherence tomography (FD-OCT) during percutaneous coronary intervention (PCI) optimisation.
Methods:
13 pairs of OCT runs were analysed, wherein each pair consisted of a contrast run and a heparinized saline run taken in the same coronary artery at the same position. Quantitative analysis was done comparing minimal lumen area (MLA), proximal reference diameter (PRD), distal reference diameter (DRD) and percentage area stenosis (AS) at the same anatomical location. Lesion morphologies, rendered stent view and 3D reconstruction were compared for image clarity.
Result:
The saline OCT runs resulted in comparable MLA (3.88 ± 2.59 mm2 with saline run vs 3.88 ± 2.71 mm2 with contrast run; p = 0.650), PRD (3.66 ± 0.52 mm with saline vs 3.65 ± 0.52 mm with contrast; p = 0.463), DRD (2.97 ± 0.22 mm with saline vs 2.99 ± 0.88 mm with contrast; p = 0.433), and AS (59.60 ± 18.62% with saline vs 59.18 ± 19.11% with contrast; p = 0.753) with respect to the contrast runs. The Bland Altman plots of the measured parameters indicate good agreement between saline and contrast OCT. Linear regression analysis indicated the absence of proportional bias All lesion morphologies (calcified, fibrotic, thin cap fibroatheroma, macrophages, cholesterol crystals and edge dissection), 3D reconstruction and rendered stent view were clearly demonstrable in the saline OCT runs.
Conclusions:
Using heparinized saline as flushing media in coronary FD-OCT may result in vessel dimensions that are comparable with contrast. Heparinized saline may be used as a contrast saving alternative for FD-OCT during PCI optimization.
More Related Videos
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography