Related Experiment Video
Updated: Nov 20, 2025

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Factors associated with extubation failure in very low birth weight infants: a cohort study in the northeast Brazil
Raphaela Farias Teixeira1,2,3, Cinthia Maria Costa3, Catarina Maria de Abreu2
1Graduate Program in Health Sciences, Federal University of Sergipe, Aracaju, Sergipe, Brazil.
Insights
Extremely low birth weight infants with prolonged ventilation, vaginal delivery, or maternal chorioamnionitis face higher extubation failure risks. This failure is linked to increased BPD and longer hospital stays for neonates.
Area of Science:
- Neonatal Intensive Care
- Pediatric Pulmonology
- Clinical Neonatology
Background:
- Extubation failure in very low birthweight (VLBW) infants poses significant challenges.
- Identifying predictive factors is crucial for optimizing extubation strategies and improving infant outcomes.
Purpose of the Study:
- To identify key risk factors associated with extubation failure in VLBW infants.
- To inform the development of refined extubation criteria in neonatal intensive care.
Main Methods:
- A cohort study involving VLBW infants undergoing their first extubation was conducted.
- Extubation failure was defined as reintubation within seven days.
- Robust Poisson regression was used to estimate relative risks of predictive variables.
Main Results:
- Extremely low birth weight, mechanical ventilation duration >7 days, vaginal delivery, and maternal chorioamnionitis were independently associated with extubation failure.
- Infants experiencing extubation failure required more respiratory support and oxygen therapy.
- Higher incidence of bronchopulmonary dysplasia (BPD) and longer hospital stays were observed in the failure group.
Conclusions:
- Specific factors like extreme prematurity, prolonged ventilation, and maternal conditions increase extubation failure risk in VLBW infants.
- Extubation failure negatively impacts infant outcomes, leading to increased BPD and extended hospitalization.
- Understanding these risk factors is vital for improving neonatal respiratory care and weaning protocols.
Objectives:
Identifying and understanding the main risk factors associated with extubation failure of very low birthweight (VLBW) infants in different populations can subsequently help in establishing better criteria while taking decision of extubation. The aim of the study was to identify factors associated with extubation failure in VLBW infants.
Methods:
A cohort study of VLBW infants who underwent their first extubation between April 2018 and December 2019 in a Neonatal Intensive Care Unit, Alagoas, Brazil, were included in this study. Extubation failure was defined as reintubation within seven days of extubation. Relative risks of predictive variables different between the extubation success group (ES) and extubation failure group (EF) were estimated with a robust Poisson regression model.
Results:
Out of the 112 infants included, 26 (23%) cases exhibited extubation failure. Extremely low birth weight (RR 2.55, 95% CI 1.07, 6.06), mechanical ventilation duration for first extubation greater than seven days (RR 2.66, 95% CI 1.10, 6.45), vaginal delivery (RR 2.07, 95% CI 1.03, 4.18) and maternal chorioamnionitis (RR 4.89, 95% CI 1.26-18.98) remained independently associated with extubation failure. EF had a significant greater need for respiratory support, longer oxygen therapy duration, more bronchopulmonary dysplasia (BPD) and longer length of hospital stay, even when adjusted for confounding variables.
Conclusions:
Extremely low birth weight infants needing mechanical ventilation, wherein the duration for first extubation was longer than seven days, with vaginal delivery and maternal chorioamnionitis failed more frequently at the first attempt of extubation. And this failure increased the risk of BPD and the length of hospital stay.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...

