Related Experiment Video
Updated: Nov 20, 2025

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Closing volume detection by single-breath gas washout and forced oscillation technique
Chiara Veneroni1, Alain Van Muylem2, Andrei Malinovschi3
1TechRes Lab, Department of Electronics, Information and Biomedical Engineering, Politecnico di Milano University, Milan, Italy.
Abstract:
Closing volume (CV) is commonly measured by single-breath nitrogen washout (CVSBW). A method based on the forced oscillation technique was recently introduced to detect a surrogate CV (CVFOT). As the two approaches are based on different physiological mechanisms, we aim to investigate CVFOT and CVSBW relationship at different degrees and patterns of airway obstruction. A mathematical model was developed to evaluate the CVSBW and CVFOT sensitivity to different patterns of airway obstruction, either located in a specific lung region or equally distributed throughout the lung. The two CVs were also assessed during slow vital capacity (VC) maneuvers in triplicate in 13 healthy subjects and pre- and postmethacholine challenge (Mch) in 12 subjects with mild-moderate asthma. Model simulations suggest that CVSBW is more sensitive than CVFOT to the presence of few flow-limited or closed airways that modify the contribution of tracer-poor and tracer-rich lung regions to the overall exhaled gas. Conversely, CVFOT occurs only when at least ∼65% of lung units are flow limited or closed, regardless of their regional distribution. CVSBW did not differ between healthy subjects and those with asthma (17 ± 9% VC vs. 22 ± 10% VC), whereas CVFOT did (16 ± 5% VC vs. 23 ± 6% VC, P < 0.01). In patients with asthma, both CVSBW and CVFOT increased post-Mch (33 ± 7% VC P < 0.001 and 43 ± 12% VC P < 0.001, respectively). CVSBW weakly correlated with CVFOT (r = 0.45, P < 0.01). The closing capacities (CV + residual volume) were correlated (r = 0.74, P < 0.001), but the changes with Mch in both CVs and closing capacities did not correlate. CVFOT is easy to measure and provides a reproducible parameter useful for describing airway impairment in obstructive respiratory diseases.NEW & NOTEWORTHY The forced oscillation technique can identify a surrogate of closing volume (CVFOT). We investigated its relationship with the one measured by single-breath washout (CVSBW). CVFOT weakly correlates with CVSBW. The respective closing capacities were correlated, but their increases after methacholine challenge in asthmatics did not. Our results suggest that CVFOT is less sensitive than CVSBW to few flow-limited/closed airways but more specific in detecting increases in flow-limited/closed airways involving the majority of the lung.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
06:11Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Respiratory Volumes and Capacities I