Related Experiment Video
Updated: Nov 20, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Radiation doses from head, neck, chest and abdominal CT examinations: an institutional dose report
Eray Atlı1, Sadık Ahmet Uyanık1, Umut Öğüşlü1
1Department of Radiology, Okan University Hospital, İstanbul, Turkey.
Purpose:
We aimed to obtain typical values for head, neck, chest, and abdominal computed tomography (CT) examinations from routine patients in 2018, and to review our data with national and international diagnostic reference levels (DRLs).
Methods:
Single-phase head, neck, chest, and abdominal CT scans of adults performed in 64-slice CT in 2018 were included in this study. Radiation dose parameters of CT scans were obtained from the picture archiving and communication system of our hospital. Volumetric CT dose index (CTDIvol) and dose length product (DLP) values were recorded. Effective dose (ED) and scan length was calculated. A 16 cm diameter phantom is referenced for head CT, and 32 cm diameter phantom is referenced for neck, chest, and abdominal CT. Descriptive statistics of the variables were given according to the normality testing.
Results:
Median CTDIvol value was 53 mGy for the head, 13.1 mGy for the neck, 8.3 mGy for the chest, and 8.6 mGy for the abdomen. Median DLP value was 988 mGy.cm for the head, 299 mGy.cm for the neck, 314 mGy.cm for the chest, and 457 mGy.cm for the abdomen. Median ED value was 2.07 mSv for the head, 1.76 mSv for the neck, 4.4 mSv for the chest, and 6.8 mSv for the abdomen. Considering national DRLs, median CTDIvol values of head, chest, and abdomen were lower, whereas median DLP and ED values of head and chest were higher. For the abdomen, the median DLP and ED values were lower.
Conclusion:
Overall radiation dose parameters obtained in this study points out the need for optimization of head CT examinations in our institution.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...