Related Experiment Video
Updated: Nov 20, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Retention-directed and selectivity controlled chromatographic resolution: Rapid post-hoc analysis of DMPK samples to
Paul Turnpenny1, Anthony Dickie1, Jed Malec1
1Evotec, Department of Drug Metabolism & Pharmacokinetics, Abingdon, Oxon, UK.
Abstract:
High quality chromatographic separation underpins robustness in LC-MS, frequently the analytical method of choice for pharmaceutical drug discovery work. The potential improvements in chromatographic selectivity afforded by serial column coupling (SCC), provide a useful means to enhance the resolution of complex samples. In this work, we present a revised high-throughput form of SCC, in which just two individual mixed phase columns were coupled together and combined with a gradient-optimised, retention-directed ultra-high pressure method to achieve rapid separations, with no further method optimisation necessary. The overall performance was evaluated from an open access DMPK analytical working environment perspective; where in anticipation of bioanalytical or metabolite identification chromatography challenges, or with the knowledge that stronger resolution was required for in-vitro sample analysis, the methodology could be immediately implemented by the analyst. Retention-directed selection of a shallow SCC gradient method was successful in separating peaks throughout the chromatographic window, resulting in a runtime still congruent to high-throughput analyses (3.5 min). In-vitro assay sample interferences were resolved 44-72% of the time, and the overall resolving power for isomeric separations significantly improved against single column comparisons (1.7-fold mean RS improvement). Over a sustained period of time in our laboratory, SCC methods have been used for metabolite identification and bioanalytical samples, where both convenience and effectiveness in solving analytical challenges has been consistently demonstrated. Examples that highlight SCC chromatography, and a guided discussion of the main high-throughput considerations, are included. The technique offers wide applicability, and we would recommend it as a toolbox consideration to the laboratory analyst.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Elution Process
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Types of Detectors