Related Experiment Video
Updated: Nov 20, 2025

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Unmasking right ventricular failure in cardiogenic shock: The importance of serial hemodynamics
Alejandro Lemor1,2, Waleed Al-Darzi1, William O'Neill1
1Department of Cardiology, Henry Ford Hospital, Detroit, Michigan.
Abstract:
A 65-year-old female was transferred with myocardial infarction, three-vessel coronary artery disease, cardiogenic shock and an intraaortic balloon pump. Given persistent shock, mechanical circulatory support (MCS) was upgraded using a left ventricular hemodynamic support device (Impella CP). The patient was monitored in the catheterization laboratory and serial hemodynamic measures were obtained. Initial hemodynamics showed relative improvement; however, serial assessments demonstrated worsening hemodynamics secondary to right ventricular failure, ultimately requiring a right ventricular hemodynamic support device. The case highlights the rapid changes that can occur with mechanical circulatory support devices and demonstrates the importance of obtaining serial hemodynamics in the cardiac catheterization laboratory.
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure II: Pathophysiology
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Heart Failure V: Medical Management
Mitral Regurgitation I: Introduction
Mitral Stenosis I: Introduction