Related Experiment Video
Updated: Nov 20, 2025

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Bioprosthetic Valve Thrombosis and Obstruction Secondary to COVID-19
Guillem Llopis Gisbert1, Verónica Vidal Urrutia1, Miguel A Moruno Benita1
1Consorci Hospital General Universitari de Valencia, Valencia, Spain.
Abstract:
Patients with COVID-19 may present a hypercoagulable state, with an important impact on morbidity and mortality. Because of this situation pulmonary embolism is a frequent complication during the course of infection. We present the case of a patient recently discharged, after admission with confirmed COVID-19, who developed a pulmonary embolism and thrombosis of a biological mitral valve prosthesis, producing valve obstruction and stenosis. After 15 days of anticoagulant treatment, resolution of the thrombus and normalisation of prosthetic valve function was observed. This case supports current recommendations of administering full-dose anticoagulation therapy to COVID-19 patients with biological heart valve prosthesis, even after the acute phase of infection.
Related Concept Videos
Venous Thrombosis I: Introduction
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Pulmonary Embolism I: Introduction
Pulmonary Embolism III: Nursing Management
Mitral Stenosis III: Medical Management