Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Photoreceptors and Visual Pathways01:22

Photoreceptors and Visual Pathways

8.0K
At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category,...
8.0K
Glaucoma: Overview01:25

Glaucoma: Overview

1.1K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.1K
Angle Closure Glaucoma: Treatment01:28

Angle Closure Glaucoma: Treatment

955
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
955
Focusing of Light in the Eye01:16

Focusing of Light in the Eye

4.1K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
4.1K
Open Angle Glaucoma: Treatment01:27

Open Angle Glaucoma: Treatment

831
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
831
Unrenewable Cells00:50

Unrenewable Cells

2.6K
In humans, the photoreceptor cells of the eye and sensory hair cells of the ear lack stem cells. These cells are thus unrenewable and cannot be replaced when they are damaged or destroyed.
Photoreceptors
The retina is composed of several layers and contains specialized cells called photoreceptors. The photoreceptors (rods and cones) change their membrane potential when stimulated by light energy. There are two types of photoreceptors—rods and cones—which differ in the shape of...
2.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Medical Therapy Algorithm With Telehealth Reduces Procedures and Transfers for Peritonsillar Abscess.

The Laryngoscope·2025
Same author

The Effect of Early Fluid Resuscitation on Mortality in Sepsis: A Systematic Review and Meta-Analysis.

Critical care medicine·2025
Same author

Evaluation of Point-of-Care Ultrasound Use in Emergency Medicine Residents: An Observational Study.

The western journal of emergency medicine·2025
Same author

Multispecialty comparison of point-of-care-ultrasound use, training, and barriers: a national survey of VA medical centers.

The ultrasound journal·2025
Same author

The crescent sign on ocular ultrasound and correlation with elevated intracranial pressure: A prospective cohort study.

The American journal of emergency medicine·2025
Same author

Cardiopulmonary Ultrasound to Predict Care Escalation in Early Sepsis: A Pilot Study.

The Journal of emergency medicine·2024

Related Experiment Video

Updated: Nov 20, 2025

Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss
07:12

Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss

Published on: April 11, 2025

697

Young Male With Vision Loss

Kevin T McConkey1, Braden A Burckhard2, Dana M Resop1

  • 1BerbeeWalsh Department of Emergency Medicine, University of Wisconsin School of Medicine and Public Health, Madison, WI.

Annals of Emergency Medicine
|January 25, 2021
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
07:06

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients

Published on: March 29, 2022

3.0K
Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

6.6K

Related Experiment Videos

Last Updated: Nov 20, 2025

Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss
07:12

Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss

Published on: April 11, 2025

697
Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
07:06

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients

Published on: March 29, 2022

3.0K
Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

6.6K