Related Experiment Video
Updated: Nov 20, 2025

Novel Mini-open Transforaminal Lumbar Interbody Fusion
Published on: June 6, 2025
Equal Ratio Ventilation Reduces Blood Loss During Posterior Lumbar Interbody Fusion Surgery
Hye Bin Kim1, Tae Dong Kweon1, Chul Ho Chang1
1Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
Study Design:
A prospective randomized double-blinded study.
Objective:
The aim of this study was to compare the effect of two different ventilator modes (inspiratory to expiratory ratio [I:E ratio] of 1:1 and 1:2) on intraoperative surgical bleeding in patients undergoing posterior lumbar interbody fusion (PLIF) surgery.
Summary Of Background Data:
During PLIF surgery, a considerable amount of blood loss is anticipated. In the prone position, engorgement of the vertebral vein increases surgical bleeding. We hypothesized that equal ratio ventilation (ERV) with I:E ratio of 1:1 would lower peak inspiratory pressure (PIP) in the prone position and consequentially decrease surgical bleeding.
Methods:
Twenty-eight patients were randomly assigned to receive either ERV (ERV group, n = 14) or conventional ventilation with I:E ratio of 1:2 (control group, n = 14). Hemodynamic and respiratory parameters were measured at 5 minutes after anesthesia induction, at 5 minutes after the prone position, at the time of skin closure, and at 5 minutes after turning to the supine position.
Results:
The amount of intraoperative surgical bleeding in the ERV group was significantly less than that in the control group (975.7 ± 349.9 mL vs. 1757.1 ± 1172.7 mL, P = 0.030). Among other hemodynamic and respiratory parameters, PIP and plateau inspiratory pressure (Pplat) were significantly lower and dynamic lung compliance (Cdyn) was significantly higher in the ERV group than those of the control group throughout the study period, respectively (all P < 0.05).
Conclusion:
Compared to conventional ratio ventilation, ERV provided lower PIP and reduced intraoperative surgical blood loss in patients undergoing PLIF surgery.Level of Evidence: 2.