Related Experiment Video
Updated: Nov 20, 2025

Capillary Electrophoresis-based Hydrogen/Deuterium Exchange for Conformational Characterization of Proteins with Top-down Mass Spectrometry
Published on: June 8, 2021
Capillary electrophoresis with dual C4D/UV detection for simultaneously determining major metal cations and whey
1College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, China. chemxzq@dhu.edu.cn.
Abstract:
A reliable and simple CE method with dual C4D and UV detection modes for simultaneous determination of major metal cations and whey proteins in milk samples was developed. Sample pretreatment comprised dilution, acidification to pH 4.55 with 10 mM AcOH and centrifugation. The complete separation of metal cations K+, Ca2+, Na+, and Mg2+ and whey proteins α-Lac, and β-Lg could be achieved respectively within 10 min and 20 min in a simple BGE composed of 1.0 M AcOH, 12 mM l-His and 2 mM 18-crown-6 with pH 2.74 at a voltage/current of +15 kV/12.5 μA. The samples were injected hydrodynamically by a pressure of 50 mbar for 5 s, the excitation voltage and excitation frequency of the C4D detector were 80 V and 1000 kHz, respectively and the detection wavelength of UV detection was set at 200 nm. In cation analysis, the range of the detection limit was 0.05-0.10 mg L-1 for C4D detection and 0.10-0.50 mg L-1 for UV detection, respectively, and the relative standard deviations (RSD%, n = 5) of intraday and interday analysis were 0.37-0.55% and 0.46-0.79% for the relative migration time, and 2.51-4.12% and 3.65-4.91% for the peak area, respectively. In whey protein analysis, the detection limits of β-Lg and α-Lac analysis were 5 mg L-1 and 3 mg L-1, respectively and the relative standard deviations (RSD%, n = 5) of intraday and interday analysis were 0.29-0.31% and 0.43-0.48% for the migration time and 2.89-3.25% and 3.29-4.18% for the peak area, respectively. The content of four major metal cations and two whey proteins in various types of milk samples was obtained. The results indicated that the content of metal cations varied little in milk samples of different brands and prices, while the content of whey proteins, as thermosensitive active proteins, varied greatly among different heat-treated milk samples.
More Related Videos
07:58Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Ion-Exchange Chromatography