Related Experiment Video
Updated: Jul 26, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Quasi-static analysis of hip cement spacers
Abdelhafid Mallek1, Abdelkader Miloudi2, Mokhtar Khaldi3
1LMPM, Department of Mechanical Engineering, University of Sidi Bel Abbes, BP 89, Cité Ben M'hidi, Sidi Bel Abbes, 22000, Algeria.
Abstract:
The use of temporary hip prosthesis made of orthopedic cement (spacer) in conjunction with antibiotics became a widespread method used for treating prosthetic infections despite the fact that this method makes bone cement (PMMA) more fragile. The necessity to incorporate reinforcement is therefore crucial to strengthen the bone cement. In this study, a validated Finite Element Modelling (FEM) was used to analyze the behavior of spacers. This FEM model uses a non-linear dynamic explicit integration to simulate the mechanical behavior of the spacer under quasi-static loading. In addition to this FEM, Extended Finite Element Method (XFEM) was also used to investigate the fracture behavior of the spacers reinforced with titanium, ceramic and stainless-steel spacer stems. The effect of the material on the performance of the reinforced spacers was also analyzed. The results showed that numerical modelling based on explicit finite element using ABAQUS/Explicit is an effective method to predict the different spacers' mechanical behavior. The simulated crack initiation and propagation were in a good agreement with experimental observations. The FEM models developed in this study can help mechanical designers and engineers to improve the prostheses' quality and durability.
Related Concept Videos
Constraints and Statical Determinacy
Method of Joints: Problem Solving I
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Soundness of Cement
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...

